Inductive NAMUR sensor | NI501A



IIB2015BN/US/1G/1D, EFECTOR M INDUCTIVE PROXIMITY SWITCH FOR POTENTIALLY EXPLOSIVE ATMOSPHERES , M30, L=51MM, METAL, SN 15MM F, ATEX GROUP II, CATEGORY 1G/2G, 1D, NAMUR SPECIFICATION, M12 CONNECTOR
- 24x7 Support +968 99 26 36 46
- Premium Quality
- 10 days Return & Exchange
- Deliver in 5-7 Days
- Worldwide Shipping
- Sellers can Quote
Original price was: ر.ع.76.500.ر.ع.73.300Current price is: ر.ع.73.300.
Inductive NAMUR sensor
NI501A
IIB2015BN/US/1G/1D
For applications in hazardous areas
For connection to intrinsically safe circuits
Clearly visible indication of the switching status
Robust metal housing for use in harsh industrial environments
Permanently legible laser type label
- For applications in hazardous areas
- For connection to intrinsically safe circuits
- Clearly visible indication of the switching status
- Robust metal housing for use in harsh industrial environments
- Permanently legible laser type label
Product characteristics
| Electrical design | NAMUR |
| Output function | normally closed |
| Sensing range[mm] | 15 |
| Housing | threaded type |
| Dimensions[mm] | M30 x 1.5 / L = 50 |
Electrical data
| Connection to switching amplifiers | yes |
| Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
| Nominal voltage DC[V] | 8.2; (1kΩ) |
| Supply voltage DC[V] | 7.5…30; (when used outside the hazardous area) |
| Current consumption[mA] | < 1; (disabled; conductive: > 2,1) |
| Protection class | II |
Outputs
| Electrical design | NAMUR |
| Output function | normally closed |
| Permanent current rating of switching output DC[mA] | 30; (when used outside the hazardous area) |
| Switching frequency DC[Hz] | 100 |
Detection zone
| Sensing range[mm] | 15 |
| Real sensing range Sr[mm] | 15 ± 10 % |
| Operating distance[mm] | 0…12.15 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
| Hysteresis[% of Sr] | 1…15 |
| Switch point drift[% of Sr] | -10…10 |
Operating conditions
| Ambient temperature[°C] | -20…70 |
| Protection | IP 67 |
Tests / approvals
| Approval | BVS 04 ATEX E 091 X; IECEx BVS 06.0003X | ||
| ATEX marking | |||
| EMC |
| ||
| Shock/vibration resistance | 30 g (11 ms) / 10-55 Hz (1 mm) | ||
| MTTF[years] | 2514 |
Safety classification
| Max. internal capacitance[nF] | 230 |
| Max. internal inductance[µH] | 210 |
Mechanical data
| Weight[g] | 162.2 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] | M30 x 1.5 / L = 50 |
| Thread designation | M30 x 1.5 |
| Materials | housing: brass special coating; sensing face: PBT; LED window: PA |
Displays / operating elements
| Display |
|
Accessories
| Items supplied |
|
Remarks
| Pack quantity | 1 pcs. |
Electrical connection – plug
| Connection | Connector: 1 x M12; coding: A |
NF5012
Inductive NAMUR sensor
IFA2002-N/6M/1D/1G
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — EN-GB — NF5012 — 20.02.2024 —
Product characteristics
Electrical design NAMUR
Output function normally closed
Sensing range [mm] 2
Housing threaded type
Dimensions [mm] M12 x 1 / L = 30
Electrical data
Connection to switching
amplifiers yes
Switching amplifiers connection to certified intrinsically safe circuits with
the max. values: U = 15 V / I = 50 mA / P = 120 mW
Nominal voltage DC [V] 8.2; (1kΩ)
Supply voltage DC [V] 7.5…30; (when used outside the hazardous area)
Current consumption [mA] < 1; (disabled; conductive: > 2,1)
Protection class III
Outputs
Electrical design NAMUR
Output function normally closed
Permanent current rating of
switching output DC
[mA] 30; (when used outside the hazardous area)
Switching frequency DC [Hz] 1200
Detection zone
Sensing range [mm] 2
Real sensing range Sr [mm] 2 ± 10 %
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3
Hysteresis [% of Sr] 1…15
Switch point drift [% of Sr] -10…10
Operating conditions
Ambient temperature [°C] -20…80
Protection IP 67
Tests / approvals
Approval PTB 01 ATEX 2191; BVS 04 ATEX E 153 X; IECEX BVS 06.0003X; TIIS TC16107
NF5012
Inductive NAMUR sensor
IFA2002-N/6M/1D/1G
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — EN-GB — NF5012 — 20.02.2024 —
ATEX marking II 1G Ex ia IIC T6 Ga Ta -20…70°C
II 1G Ex ia IIC T5 Ga Ta -20…80°C
II 1D Ex ia IIIC T200 90°C Da Ta: -20…70°C
II 1D Ex ia IIIC T200 100° C Da Ta: -20…80°C
EMC EN 60947-5-6
Shock/vibration resistance 30 g (11 ms) / 10-55 Hz (1 mm)
MTTF [years] 4736
Safety classification
Max. internal capacitance [nF] 141
Max. internal inductance [µH] 344
Mechanical data
Weight [g] 254
Housing threaded type
Mounting flush mountable
Dimensions [mm] M12 x 1 / L = 30
Thread designation M12 x 1
Materials brass white bronze coated; sensing face: PC
Accessories
Items supplied lock nuts: 2
Remarks
Pack quantity 1 pcs.
Electrical connection
Cable: 6 m, PVC; 2 x 0.34 mm²
Connection
Core colours :
BN = brown