Control Cable 4C x 14 AWG / 0.6 – 1KV LIYCY

This is a flexible, multi-core control cable with four conductors, each made of 14 AWG (American Wire Gauge) stranded copper. It is designed for applications requiring a voltage rating of 0.6 to 1 kilovolt (kV).
- 24x7 Support +968 99 26 36 46
- Premium Quality
- 10 days Return & Exchange
- Deliver in 5-7 Days
- Worldwide Shipping
- Sellers can Quote
ABOUT THIS ITEM
Control Cable 4C x 14 AWG / 0.6 – 1KV LIYCY
APPLICATION
Screen flex® 110/200 LIYCY CONTROL CABLE VC4V-K is a screened control cable. It is
used in all types of signal transmission connections where the
voltage induced by an exterior electromagnetic field may affect the
signal transmitted.
Its most common applications are control circuits, electronic
equipment connections, computer systems, etc.
CONSTRUCTION
Conductor
Electrolytic annealed copper, class 5 (flexible) according to EN 60228
and IEC 60228.
Insulation
Flexible PVC type TI2 according to EN 50363-3 and type PVC/A
according to IEC 60502-1.
The standard identification of insulated conductors according to HD
308 and EN 50334 is the following:
1 x
Natural
2 x
3 G
3 x
4 G
4 x
5 G
Blue + Brown
Blue + Brown + Green/Yellow
Brown + Black + Grey
Brown + Black + Grey + Green/Yellow
Brown + Black + Grey + Blue
Brown + Black + Grey + Green/Yellow + Blue
6 or more Black numbered + Green/Yellow.
Other identifications (JZ, OZ, J, O) are available on request.
Screen
Aluminum-polyester tape screen with overlapping tinned copper
braid, ensuring full screening coverage.
Outer sheath
Flexible PVC type TM2 according to EN 50363-4-1 and type ST1
according to IEC 60502-1.
Black or grey color (grey for fire non-propagation).
The ripcord allows you to gently tear the outer-sheath and remove it
without damaging the screen.
CHARACTERISTICS
Electrical performance
Low voltage: 300/500 V. (up to 1,5 mm2).
0,6/1 kV (from 2,5mm
Thermal performance
2onwards).
Maximum conductor temperature: 70°C.
Maximum short-circuit temperature: 160°C (max. 5 s).
Minimum service temperature: -40°C (static, with protection).
Fire performance
Flame non-propagation according to EN 60332-1 / IEC 60332-1.
Fire non-propagation according to EN 60332-3 / IEC 60332-3 (only
grey outer sheath).
Reaction to fire CPR according to EN 50575:
Cca -s2, d1, a3 (grey outer sheath 300/500 V)
Cca -s3, d1, a3 (grey outer sheath 0,6/1 kV).
Eca (black outer sheath).
Low halogen emission. Chlorine < 15%.
Mechanical performance
Minimum bending radius: 5x cable diameter.
Impact resistance: AG2 Medium severity.
Environmental performance
Chemical & Oil resistance: Good.
UV Resistant according to UNE 211605.
Water resistance: AD5 Jets.